Unit Configuration
Table
(2 of 2)
Backup Configuration Options
RestorTimOut: 5m
Next Chang Prev
Restoration
Chang Ð Calls up a data entry display for changing the current value, with a range of 1 to 60 minutes.
TriesTimeOut:15m
Next Chang Prev
Call Attempts
Only 10 call attempts are made for the normal calling cycle. If a call attempt is in progress and the timer expires, the call attempt will not be aborted.
Chang Ð Calls up a data entry display for changing the current value, with a range of 1 to 60 minutes.
MultiCall:Disab
Next Enab Disab Prev
Multiple Calls. Selects the multiple calling cycle in which the DBM steps through the Backup Directory, attempting to call each valid dial string in the directory, or selects the normal calling cycle. This configuration option only has an effect if Auto Bckup is set to Enab or if DTRCallCon is set to Orig.
Enab | Ð | The DBM makes one attempt to call the dial string in the directory pointed to in the Backup Directory |
|
| configuration option (default is the first dial string in the directory). If the attempt fails, the DBM makes an |
|
| attempt to call the next dial string in the directory, and so on until either a call is completed or the DBM |
|
| cycles through all the dialed strings in the Backup Directory, ignoring blank entries. The DBM then waits |
|
| five minutes and begins the calling cycle again until the TriesTimeOut period expires. |
Disab | Ð | The normal calling cycle is used: three call attempts, a |
|
|
NOTE: Multicall must not be enabled unless successive telephone numbers in the Backup Directory are different. In addition, duplicate telephone numbers should be avoided. These precautions prevent the DBM from making excessive call attempts to the same telephone number.
December 1996 |