Connecting to the NMS

A 3600 Hubbing Device is required to connect the control DSU to the 6700 or 6800 Series NMS. When connected to the NMS, the DSU can be controlled and configured from the NMS rather than from the DCP alone.

.Procedure

1.Plug the 4-pin modular plug of the 3600 Hubbing Device (Figure 2-3) into the DSU jack labeled CC/DC.

2.Plug one end of an M6BJ cable into the hubbing device jack labeled CC IN/DC OUT.

3.Plug the other end of the 6-pin M6BJ cable into the 6-pin end of the 873A adapter.

4.Plug the D-type end of the 873A adapter into the appropriate 6700 or 6800 Series NMS jack.

Refer to your COMSPHERE 6700 or 6800 Series NMS documentation to control and configure the DSU from the NMS.

Connecting to the Dial (or PSTN) Network

If your DSU is equipped with a V.32 DBM, refer to Figure 2-4 as you follow these steps.

.Procedure

1.Plug either end of the dial (analog) interface cable into the DSU jack labeled BACKUP.

Permissive service ± telephone cord with 6-pin modular RJ11C plug

Programmable service ± telephone cord with 8-pin RJ45S plug

2.Plug the other end of the cable into the modular jack provided by the telephone company, USOC RJ11C (permissive) or USOC RJ45S (programmable).

3.If your site has programmable service, verify that the DSU's hardware strap S1-1 is switched to the OFF position.

NMS NETWORK

CONNECTION

LOW VOLTAGE

AC POWER IN

TO

NMS (873A)

CC/DC

 

 

DEVICE

3000HUBBING

-F3-300

MODEL

#3000

 

 

HUBBING

DEVICE 496-14576aFigure 2-4. Model 3615 DSU

Dial (PSTN) Network Connection

Figure 2-3. Model 3615 DSU

NMS Connection

2-6

December 1996

3615-A2-GB20-20

Page 26
Image 26