Paradyne 3616 DSR FrcOn Enab Next Enab Disab Prev, DSR on Tst Enab Next Enab Disab Prev, ExtLd

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 79
Image 79

COMSPHERE DualFlow Data Service Units

Table 5-4

(2 of 3)

DBM Port Configuration Options

DSR FrcOn: Enab

Next Enab Disab Prev

Data Set Ready Forced On. Provides the ability to override any other options controlling the Data Set Ready lead.

Enab

Ð

DSR remains ON as long as the device is working regardless of tests and network alarms.

Disab

Ð

DSR functions as an active lead reflecting various test and alarm conditions and other options.

DSR on Tst: Enab

Next Enab Disab Prev

Data Set Ready On in Test. Controls the behavior of the DSR lead during testing.

Enab

Ð

DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test

 

 

messages to the DBM.

Disab

Ð

DSR is Off during testing.

RespondRDL: Disab

Next Enab Disab Prev

Respond to Remote Digital Loopback. Determines whether the DBM responds to a V.54 Remote Loopback request.

Enab

Ð

Performs a Digital Loopback.

Disab

Ð

Ignores the Loopback command.

RL by DTE: Disab

Next Enab Disab Prev

Remote Digital Loopback by DTE. Allows Pin 21 of the EIA-232-D/V.24 interface or Pin N of the V.35 interface by the DTE or router to initiate a Remote Digital Loopback.

NOTE: Use of Pin 18 or Pin L is determined by the DBM's DTE Port configuration option.

Enab

Ð

The DTE or router forces the DBM to request a Remote Digital Loopback when the signal on Pin 21 or

 

 

Pin N is turned ON. Remote Digital Loopback ends when the signal is dropped.

Disab

Ð

The DTE or router cannot initiate Remote Digital Loopback.

Bilat Lpbk: Disab

Next Enab Disab Prev

Bilateral Loopback. If this configuration option is enabled, a DTE Loopback occurs when a Digital Loopback occurs.

Enab

Ð

When enabled, DTE Loopback occurs whenever a Digital Loopback occurs.

Disab

Ð

Disables Bilateral Loopback.

Ext Leads: Rate

Next ExtLd Rate RPowr Prev

External Leads. Controls the general-purpose leads on the EIA-232-D/V.24 interface except when Rate is selected. These leads can be controlled and monitored from the DCP or a 6700 or 6800 Series NMS.

ExtLd

Ð

Enables Pins 12 and 13 as output (control) and Pins 19 and 23 as input (alarm) leads. When enabled,

 

 

Pins 12 and 13 output +12V when ON and ±12V when Off. Pins 19 and 23 recognize voltages from +2.2V

 

 

to +12V as ON (reported as an External alarm) and ±12V to +.8V as Off.

Rate

Ð

Pin 12 on the port is turned Off to indicate that the DBM is in fallback mode. If the port does not fall back

 

 

and remain at the same speed, then the fallback feature in the DCE or router connected to that port

 

 

should not be enabled.

RPowr

Ð

Functions similarly to ExtLd, but the inputs report power failure or fan alarms when a redundant power

 

 

supply is installed in the COMSPHEREr 3000 Series Carrier.

5-14

December 1996

3615-A2-GB20-20

Page 79
Image 79
Paradyne 3616, 3615 manual DSR FrcOn Enab Next Enab Disab Prev, DSR on Tst Enab Next Enab Disab Prev, ExtLd, Rate, RPowr