Paradyne 3616, 3615 manual Installing the Model DualFlow DSU, Before You Begin

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 21
Image 21

Installing the Model 3615

2

 

DualFlow DSU

Overview

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

 

Before you Begin

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

 

How to Change Hardware Straps

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2

 

Where to Place the DSU

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

 

Installing the DSU

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

 

Power-up Routine

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

 

Connecting to the Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

 

Connecting to the NMS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

 

Connecting to the Dial (or PSTN) Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

 

Connecting to the Switched 56 kbps Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

 

Connecting to the DDS (or LADS) Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

 

Connecting the DSU to a Router

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9

 

Addressing the Unit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

 

Tributary DSU Addressing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

 

Verifying Operation and Testing Connections

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10

 

Verifying DBM Operation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

 

Verifying Network Addresses

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

 

Verifying the Network

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12

 

Other Tests

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12

 

Overview

The Model 3615 DualFlow DSU is designed for desktop operation and is delivered ready to connect to the network. It is configured as a tributary DSU for operation at 56 kbps on a point-to-point circuit.

Installation consists of the following steps, which should be performed in the order listed.

Physical installation

Hardware straps

Electrical connection

Network diagnostic connection

Software configuration

DDS network (or LADS) connection

Dial network (or PSTN) connection

Router connection

Verification testing

Although the Model 3615 DualFlow DSU is designed for desk or table-top operation, you can order an ACCULINKr 3100 Series CSU wall-mount adapter if you want to mount the DSU on a wall, an equipment shelf, a 19-inch RS-310-C or 23-inch AT&T DATAPHONEr equipment cabinet. Refer to Appendix F to order the adapter.

Before You Begin

Your installation site should be clean, well-lighted, well-ventilated, and free from environmental extremes.

A dedicated grounded ac outlet that is protected by a circuit breaker should be installed within 6 feet of the DSU's planned location. The outlet should be capable of supplying 90 to 132 Vac 60 Hz (U.S. and Canada). At the branch site, the circuit must be capable of supplying a minimum of 2 amperes at 115 Vac. Refer to the Technical Specifications section in Chapter 1 for additional power requirements.

3615-A2-GB20-20