Paradyne 3615, 3616 manual Diagnostic General Configuration Options, Trib

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 82
Image 82

Unit Configuration

Table 5-6

Diagnostic General Configuration Options

Position: Cntrl for SyBC, Trib for DiDg and SyBT configurations

Next Cntrl Trib Prev

Network Position. Determines the DSU's position in the network, and defines its test and diagnostic capabilities.

Cntrl Ð Control

Trib

Ð

Tributary

RemoteDiag:Enhan

Next V.54 Enhan Prev

Remote Diagnostics. Determines the type of loopback message generated by a DBM.

V.54

Ð

The V.32

DBM generates a CCITT V.54 loopback sequence. This selection does not appear for a

 

 

Switched 56 DBM.

 

 

 

 

Enhan

Ð

The V.32

DBM uses enhanced 3600e protocol and the Switched 56 DBM uses Br56. Both the control and

 

 

tributary must be set for Enhan.

 

 

 

 

 

 

 

 

 

 

Link Delay: 0s

 

 

 

 

 

 

Next

0s

1s

2s

5s

10s

20s

50s

Prev

 

 

 

 

 

 

 

 

 

Link Delay. Controls the additional time (in seconds) that a control DBM will wait for a response from a device one level downstream. This configuration option does not appear when Diag Type (Diagnostic DBM option set) is set to Disr and Position is set to Trib (DiDg and SyBT configurations); this configuration option only appears for a DBM configured as a control.

NOTE: If diagnostic time-outs are occurring during polling, increase the link delay to the next higher value.

0s to 50s

Ð

Sets the time the DBM will wait for a downstream device response.

Packet Delay: 0s

 

 

 

Next

0s

1s

2s

5s

Prev

 

 

 

 

 

 

Packet Delay. Controls the time (in seconds) that a control DBM will wait for a packet to complete from an NMS. This configuration option only appears for a DBM configured as a control.

NOTE: Must be used when the DualFlow DSU's diagnostic channel operates over packet switch, satellite communications, or other facilities that provide extended throughput delays.

0s to 5s Ð Sets the time the DBM will wait for the NMS.

3615-A2-GB20-20

December 1996

5-17

Page 82
Image 82