COMSPHERE DualFlow Data Service Units
CTS | The state of the |
Data Service Unit | A DCE device that interprets, interfaces, and provides timing and signal control |
(DSU) | between a DTE device and a digital network. |
Data Terminal Equipment | A computer or peripheral device, such as a terminal or printer; a data source or sink. |
(DTE) |
|
DBM | The dial backup module for the DualFlow DSU. This module provides an alternate |
| data path for carrying router data. Three types of DBMs are available: V.32 DBMs |
| (14.4 kbps) for backup through the PSTN (dial network), |
| DBMs for backup through the |
| Switched 56 DBMs for backup through the |
| (The |
DDS | Digital Data Service, such as ACCUNET Spectrum of Digital Services, that |
| provides digital (not dial) communication circuits. |
dedicated backup | A dial backup module (DBM) assigned to a particular DSU that is continually |
| available for service restoral. The DBM switches to Dial Backup mode |
| automatically if the router detects data errors; no switching is required. |
Diagnostic Control Panel | The face of the Model 3615 DualFlow DSU that continuously provides status |
(DCP) | information about the DSU's operation and allows an operator to manage its |
| operation. This is a generic term used for both the standalone and |
| DSU models. See shared diagnostic control panel (SDCP) for the Model 3615 |
| DualFlow DSU. |
dial string | A sequence of up to 36 characters that the DBM can send into the dial network to |
| establish a call to a remote backup device. It consists of a telephone number and |
| may include other information, such as a callback directory pointer. |
DIP switch | Dual |
Direct Distance Dialing | Telephone exchange service, the Public Switched Telephone Network (PSTN or |
(DDD) | dial network) that enables a telephone service user to access telephone lines without |
| operator assistance. |
DMI | Data Mode Idle. Refers to a sequence of 1s transmitted or received on the DDS or |
| Switched 56 kbps network. When the DSU Port and DBM Port branch |
| configuration option RTS Cntrl is set to FrcOn, the DSU will transmit DMI |
| whenever RTS is Off. Data Mode Idle operation is recommended for |
| applications. and is also used for Switched 56 kbps call set up signaling. |
DSR | The state of the Data Set Ready lead (V.24 circuit 107). |
DTR | The state of the Data Terminal Ready lead (V.24 circuit 108). |
errored second | A performance measurement reported during a Digital Test that is defined as a |
| second in which at least one error has been detected. |
Facility Alarm | A failure condition reported to the NMS when there is a break in communication |
(FA) | with one or more tributary. |