Paradyne 3616, 3615 manual Device Health and Status Messages, Message Condition, Table C-3

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 95
Image 95

COMSPHERE DualFlow Data Service Units

 

 

 

Table C-3

 

 

 

(1 of 3)

 

Device Health and Status Messages

 

 

 

 

Message

 

 

Condition

 

 

CMI Fac Alarm

Facility Alarm on CMI (FacAlOnCMI) configuration option is enabled and control mode

 

idle (CMI) is being received.

 

 

Config Corrupt

Configuration is corrupt. Reset all configuration options from one of the default

 

(factory-loaded) option sets stored in the DiDg, SyBC, or SyBT area.

 

 

DBM:Device Fail

Internal failure is detected in the DBM.

 

 

DBM:Disable

DBM transmitter is disabled. DBM is in Idle mode, but no calls can be initiated or

 

answered.

 

 

 

 

DBM F: alarm

A DBM facility alarm; alarm is one of the following network alarms:

 

BiplrVio

l

Ð Excessive Bipolar Violations

 

FDHP Lost

Ð High-level communication over the signaling channel switch

 

 

 

has been lost (2-Wire Switched 56 DBM only)

 

OutofServc

Ð Out-of-Service condition (4-Wire Switched 56 DBM only)

 

No Signal

Ð No signal has been received (Switched 56 DBM only)

 

 

nn.nDBM:mode

nn.n indicates the DBM speed; mode is one of the following:

 

Standby

Ð

A dialed connection is made, but the data is still routed over the DDS

 

 

 

circuit. The first line shows the dial backup connection time.

 

Active

Ð

A dialed connection is made, and data has been routed over that line.

 

 

nn.nExternBU

nn.n indicates the external DBU's speed:

 

External

Ð

Backup is in progress on an external DBU. (DDS line is

 

Bkup

 

disabled.)

 

 

DBMTst: test,init

The DBM is running a test, initiated from init.

 

test is one of the following tests:

 

BERT

Ð

Bit Error Rate Test

 

BiL

Ð

Bilateral Loopback

 

Dev

Ð

Device Test

 

DL

Ð

Digital Loopback

 

DT

Ð

Digital Test

 

DTE

Ð

DTE Loopback

 

E-E

Ð

End-to-End Test

 

Lamp

Ð

Lamp Test

 

NetL

Ð

Network Loopback (Switched 56 DBM only)

 

RL

Ð

Remote Digital Loopback

 

TM

Ð

Test Mode

 

init is one of the following initiators:

 

DCP

Ð

Diagnostic Control Panel

 

DTE

Ð

Data T erminal Equipment

 

NMS

Ð

Network Management System

 

Remt

Ð

Remote DSU

 

 

 

 

C-4

December 1996

3615-A2-GB20-20

Page 95