Traps

Event

Severity

Comment

Trap #

MIB

 

 

 

 

 

xDSL margin

normal

Margin estimate now above

103

hot_xdsl.mib

normal

 

customer set threshold.

 

(Enterprise MIB)

 

 

 

 

 

xDSL port

major

Processor detected bad DSL

5

hot_xdsl.mib

failure

 

modem chip set.

 

(Enterprise MIB)

 

 

 

 

 

xDSL port

normal

Processor now communicating

105

hot_xdsl.mib

operational

 

with DSL modem.

 

(Enterprise MIB)

 

 

 

 

 

xDSL port

warning

Port speeds decreased to lower

2

hot_xdsl.mib

speed low

 

bound thresholds.

 

(Enterprise MIB)

 

 

 

 

 

xDSL port

normal

Port speed now above lower

102

hot_xdsl.mib

speed normal

 

bound threshold.

 

(Enterprise MIB)

 

 

 

 

 

xDSL port

normal

Port speed now above lower

102

hot_xdsl.mib

speed normal

 

bound threshold.

 

(Enterprise MIB)

 

 

 

 

 

xDSL SN

warning

Self-test failure from an

19

hot_xdsl.mib

selftest fail

 

Service Node.

 

(Enterprise MIB)

 

 

 

 

 

xDSL test start

normal

Test started by any means.

6

hot_xdsl.mib

 

 

 

 

(Enterprise MIB)

 

 

 

 

 

xDSL test clear

normal

Test over.

106

hot_xdsl.mib

 

 

 

 

(Enterprise MIB)

 

 

 

 

 

Dynamic filter

warning

Cannot inject or delete

10

hot_dhcp.mib

injection failure

 

dynamic filters to Service Node

 

(Enterprise MIB)

 

 

on port n.

 

 

 

 

 

 

 

Ethernet link

major

Ð

2

MIB II

down

 

 

 

(RFC 1213)

 

 

 

 

 

Ethernet link up

normal

Ð

3

MIB II

 

 

 

 

(RFC 1213)

 

 

 

 

 

Warm start

warning

Power on reset.

1

MIB II

 

 

 

 

(RFC 1213)

 

 

 

 

 

Self-test failure

minor

Sent if any portion of the

16

hot_sys.mib

 

 

Access Node's restart/self-test

 

(Enterprise MIB)

 

 

fails.

 

 

 

 

 

 

 

SN device

major

Operating software has

18

hot_xdsl.mib

failure

 

detected an internal device

 

(Enterprise MIB)

 

 

failure but the Service Node is

 

 

 

 

operating.

 

 

 

 

 

 

 

SN device

minor

Service Node identified on

07

hot_xdsl.mib

mismatch

 

port n does not match device

 

(Enterprise MIB)

 

 

described in port configuration

 

 

 

 

role.

 

 

 

 

 

 

 

SN device

minor

Service Node on port n now

107

hot_xdsl.mib

mismatch clear

 

matches port configuration

 

(Enterprise MIB)

 

 

table.

 

 

 

 

 

 

 

SN fatal reset

Ð

Variable binding field contains

20

hot_xdsl.mib

 

 

device failure code.

 

(Enterprise MIB)

 

 

 

 

 

B-2