Operation and Maintenance

System and Test Status Messages

System and test status information is selected from the Status menu.

Main Menu → Status → System and Test Status

The following information is included on this screen:

HSelf-Test Results Messages

HLast System Reset Date and Time

HHealth and Status Messages

HTest Status Messages

Self-Test Results Messages

One of these self-test result messages appear in the Self-Test Results field at the top of the System and Test Status screen.

Table 6-6. Self-Test Results Messages

Message

What It Indicates

What To Do

Failure xxxxxxxx

An internal failure occurred (xxxxxxxx represents an

8-digit hexadecimal failure code used by service personnel).

Record the failure code before resetting the unit; otherwise, the error information will be lost.

1.Record the failure code.

2.Reset the unit.

3.Contact your service representative.

Passed

No problems were found during power-on or reset.

No action needed.

Last System Reset Date and Time

This field indicates the last time the FrameSaver unit was reset. It appears after the Self-Test Results field at the top of the System and Test Status screen.

HDate is in mm/dd/yyyy format (month/day/year).

HTime is in mm:ss format (minutes:seconds).

9783-A2-GB20-00

July 2000

6-13