Paradyne 9783, FrameSaver DSL manual Alarm Conditions 2 What It Indicates What To Do

Models: FrameSaver DSL 9783

1 233
Download 233 pages 22.17 Kb
Page 148
Image 148

Troubleshooting

Table 8-1. Alarm Conditions (2 of 4)

Alarm Condition

What It Indicates

What To Do

 

 

 

LMI Down,

The Local Management

For the network interface:

frame relay link 2

Interface is down for the

H If LMI was never up, verify

 

specified frame relay link.

 

that the LMI Protocol setting

 

 

 

 

reflects the LMI type being

 

 

used.

 

 

H If LMI was never up:

 

 

± Verify that the proper time

 

 

slots have been configured.

 

 

± Verify that the LMI Protocol

 

 

setting reflects the LMI type

 

 

being used.

 

 

H Verify that Frame Relay

 

 

Performance Statistics show

 

 

LMI frames being transmitted.

 

 

If all of the above have been

 

 

verified and the physical link is

 

 

not in Alarm, contact your

 

 

network provider.

 

 

 

LMI Down,

The Local Management

For user data port:

frame relay link 2

Interface is down for the

H Check that the DTE cable is

 

specified frame relay link.

 

securely attached at both

 

 

 

 

ends.

 

 

H Verify that Transmit Clock

 

 

Source and Invert Transmit

 

 

Clock options are properly

 

 

configured.

 

 

H Verify that Frame Relay

 

 

Performance Statistics show

 

 

LMI frames being received. If

 

 

no frames are being received:

 

 

± Check the attached device.

 

 

± Verify that the LMI Protocol

 

 

setting reflects the LMI type

 

 

being used.

 

 

 

LOS at Network 1

A Loss of Signal (LOS)

 

 

condition is detected on the

 

 

network interface. Clears

 

 

when a signal is detected.

 

 

H Network cable problem.

H Check that the network cable

 

 

is securely attached at both

 

 

ends.

 

H No signal is being

H Check far-end FrameSaver

 

transmitted at the far-end

unit status.

 

FrameSaver unit.

 

 

 

 

2 frame relay link is one of the following:

± Net1-FR1. The frame relay link specified for the network port, Network 1.

± Port-1. The frame relay link associated with the user data port.

8-8

July 2000

9783-A2-GB20-00

Page 148
Image 148