User Interface and Basic Operation

2-5

9783-A2-GB20-00 July 2000
Screen Work Areas

There are two user work areas:

HScreen area – Where you input information into fields.

HFunction keys area – Where you perform specific screen functions.

main/config/system/slv 9783. .
Device Name: Node A 05/13/2000 02:02
SERVICE LEVEL VERIFICATION SYSTEM OPTIONS
SLV Sample Interval (secs): 60
SLV Delivery Ratio: Disable
DLCI Down on SLV Timeout: Enable
SLV Timeout Error Event Threshold: 3
SLV Timeout Clearing Event Threshold: 1
SLV Packet Size (bytes): 64
SLV Synchronization Role: Tributary
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save
Menu Path
Screen
Area
Device
Name
Model Number
Date and Time
Function
Keys Area
Message Area

Screen Format Description

Menu Path Menu selections made to reach the current screen.
Device Name Customer-assigned identification of the FrameSaver unit.
9783
FrameSaver unit’s model number.
Thi i t it it th t t 8PVC
9783
9783
-
C
HThis is a remote-site unit that supports 8 PVCs.
H
Thisis a central
-
siteunit that supports 64 PVCs
9783-
C
9783-SLV
H
Thi
s
i
s a centra
l
-s
i
te un
i
t t
h
at supports 64
PVC
s.
HThis is a remote-site unit that supports 8 PVCs and has the
9783-SLV
9783-C-SLV
HThis
is
a
remote-site
unit
that
supports
8
PVCs
and
has
the
advanced SLV feature set installed.
HThisis a central-site unit that supports 64 PVCs and has the
9783-C-SLV HThis is a central-site unit that supports 64 PVCs and has the
advanced SLV feature set installed.
Screen Area Selection, display, and input fields for monitoring and maintaining the
FrameSaver unit.
Function Keys
Area Specific functions that can be performed by pressing a specified key,
then pressing Enter.
Message Area System-related information and valid settings for input fields in the
lower left corner.
System and Test Status messages in the lower right corner.