SNMP MIBs and Traps, and RMON Alarm Defaults

Trap: warmStart

This trap indicates that the FrameSaver unit has been reset and has stabilized.

Table B-3. warmStart Trap

Trap

What It Indicates

Possible Cause

 

 

 

warmStart

FrameSaver unit has just

H Reset command sent.

 

reinitialized and stabilized

H Power disruption.

 

itself.

 

 

 

 

String:

 

Variable-Binding

 

`Unit reset.'

 

 

 

 

devLastTrapString

 

 

(devHealthAndStatus. mib)

 

 

 

 

Trap: authenticationFailure

This trap indicates that access to the FrameSaver unit was unsuccessful due to lack of authentication.

Table B-4. authenticationFailure Trap

Trap

What It Indicates

Possible Cause

 

 

 

authenticationFailure

Access to the FrameSaver

H SNMP protocol message not

 

unit was attempted and

properly authenticated.

 

failed.

H Three unsuccessful attempts

 

 

 

 

were made to enter a correct

 

 

login user ID/password

 

 

combination.

 

 

H IP Address security is enabled

 

 

and a message was received

 

 

from the SNMP Manager

 

 

whose address was not on the

 

 

lost of approved managers.

 

 

String:

 

 

`Unauthorized access attempted.'

 

 

 

 

Variable-Binding

 

 

 

 

 

devLastTrapString

 

 

(devHealthAndStatus. mib)

 

 

 

 