Troubleshooting

PVC Loopback

The PVC Loopback loops frames back to the selected interface on a per-PVC basis. This test logically (not physically) loops back frames received from another FrameSaver device through the selected frame relay PVC to the same device.

Main Menu → Test → Network PVC Tests

Network PVC Loopback

DTE

PVC #x

Network

PVC #x

98-16186

Main Menu → Test → Data Port PVC Tests

Port PVC Loopback

DTE

PVC #x

PVC #x

Network

98-16187

Send Pattern

This test sends packets filled with a hexadecimal 55 test pattern and sequence number over the selected interface and DLCI to another FrameSaver device.

To send a pattern test on a link:

Main Menu → Test → [Network PVC Tests/Data Port PVC Tests]

If the selected

Then . . .

And the default

DLCI is configured as . . .

Rate (kbps) setting is . . .

 

 

 

Standard

(Disruptive) appears

100% of CIR

 

after Test

 

 

 

 

Multiplexed

(Non-Disruptive)

10% of CIR

 

appears after Test

 

 

 

 

If the CIR is zero, the pattern will be sent at a rate of 1000 bps.

9783-A2-GB20-00

July 2000

8-19

Page 159
Image 159
Paradyne FrameSaver DSL, 9783 manual PVC Loopback, Send Pattern, Main Menu → Test → Network PVC Tests