Paradyne FrameSaver DSL, 9783 manual Alarm Conditions 3 What It Indicates What To Do

Models: FrameSaver DSL 9783

1 233
Download 233 pages 22.17 Kb
Page 149
Image 149

Troubleshooting

Table 8-1. Alarm Conditions (3 of 4)

Alarm Condition

What It Indicates

What To Do

 

 

 

Loss of Cell

The ATM Transmission

Contact your network provider.

Delineation, atm link

Convergence (TC) layer

 

 

 

has been in an LCD state

 

 

 

for one minute, or the

 

 

 

number of Out of Cell

 

 

 

Delineation (OCD)

 

 

 

delineation events has

 

 

 

exceeded the

 

 

 

user-specified threshold.

 

 

 

 

Network Com Link

The communication link for

Check the router connected to

Down

the COM port is down and

the COM port.

 

 

the COM port is configured

 

 

 

for Net Link.

 

 

 

 

OOF at Network 1

An Out of Frame (OOF)

 

 

 

condition is detected on the

 

 

 

network interface.

 

 

 

H Incompatible framing

H Check that the framing format

 

 

format between the

for the network interface is

 

 

network and the

correct.

 

 

FrameSaver unit.

 

 

 

H Network cabling

H Check that the network cable

 

 

problem.

is securely attached at both

 

 

 

ends.

 

 

 

Self-Test Failure

The unit did not pass its

H Reset the unit.

 

 

basic verification tests

H Contact your service

 

 

when it was powered on or

 

 

representative.

 

 

reset.

 

 

 

 

 

 

SLV Timeout,

An excessive number of

Verify that the network LMI is up.

DLCI nnnn,

SLV communication

If it is, contact your network

frame relay link 1, 2

responses from the remote

service provider.

 

 

system have been missed

 

 

 

on the specified multiplexed

 

 

 

DLCI and link.

 

 

 

If the frame relay link is

 

 

 

Net1-FR1, the timeout is on

 

 

 

the network FrameRly1

 

 

 

timeslot assignment.

 

 

 

When a hardware bypass-

 

 

 

capable device has been

 

 

 

detected at the other end of

 

 

 

the PVC and this condition

 

 

 

occurs, only user data for

 

 

 

EDLCI 0 will be transmitted

 

 

 

as long as the condition

 

 

 

exists.

 

 

 

 

 

1

nnnn indicates a DLCI number of 16 through 1007.

 

2

frame relay link is one of the following:

 

 

± Net1-FR1. The frame relay link specified for the network interface, Network 1.

 

± Port-1. The frame relay link associated with the user data port.

 

 

 

 

9783-A2-GB20-00

July 2000

8-9

Page 149
Image 149
Paradyne FrameSaver DSL, 9783 manual Alarm Conditions 3 What It Indicates What To Do