Configuration Options
4-23
9783-A2-GB20-00 July 2000

Table 4-10. PVC Connection Options (2 of 2)

Destination Link
Possible Settings: Net1-FR1
Default Setting: Initially blank; no default.
Specifies the frame relay interface used as the destination link; the to end of a from-to
link. The only valid settings for this configuration option are frame relay interfaces that
have at least one DLCI or EDLCI defined which are not part of a PVC connection or
management link. For example, if the network interface has no DLCIs defined, Net1-FR1
would not appear as a valid setting.
Net1-FR1 – Specifies the Network interface as the destination link.
Destination DLCI
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the destination DLCI for a frame relay interface. The DLCI must be defined
and cannot be part of a PVC connection or management link. For multiplexed DLCIs, at
least one EDLCI must be unconnected for the DLCI to be a valid selection.
NOTES: Primary Destination DLCI has no value if Primary Destination Link
contains no value.
For the basic feature set, only one EDLCI per multiplexed DLCI may be
used in the PVC connection.
16 – 1007 – Specifies the DLCI number.
Destination EDLCI
Possible Settings: 0 – 62
Default Setting: Initially blank; no default.
Specifies the destination Embedded Data Link Connection Identifier (EDLCI) for a frame
relay interface when a multiplexed DLCI record is selected as one end of a connection.
Display Conditions
– This option only appears when the Primary Destination DLCI
contains a multiplexed DLCI record number.
0 – 62 – Specifies the EDLCI number.