Operation and Maintenance

6-19

9783-A2-GB20-00 July 2000
PVC Connection Status
PVC connection statuses are selected from the Status menu.
Main Menu
Status

PVC Connection Status

Only PVC connections with Source DLCIs configured to be Active are shown.
This screen only appears when Service Type is set to Frame Relay.
PVC Connection Status Screen Example
main/status/connections 9783
Device Name: Node A 05/13/2000 06:03
Page 1 of 2
PVC CONNECTION STATUS
Source Primary Destination
Link DLCI EDLCI Link DLCI EDLCI Status
Port-1 201 Net1-FR1 300 0 Active
Port-1 202 Net1-FR1 1001 0 Active
Port-1 100 Net1-FR1 1001 2 Active
Port-1 204 Net1-FR1 1001 2 Active
Mgmt PVC Mgm205 Net1-FR1 (0,35) Active
Port-1 206 Net1-FR1 1001 Active
Port-1 207 Net1-FR1 1001 Active
Port-1 208 Net1-FR1 500 Active
Port-1 209 Net1-FR1 502 2 Inactive
Port-1 210 Net1-FR1 504 2 Inactive
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
ESC for previous menu MainMenu Exit
Refresh PgUp PgDn
If the No PVC Connections message appears instead of a list of PVC
connections, no PVC connections have been configured yet.
Table 6-9. PVC Connection Status (1 of 2)
Field Status What It Indicates
Link Identifies the cross-connection of
DLCIs configured for the unit.
Net1-FR1 HSource/destination is frame relay
link 1 on Network 1
Port-1 HUser data port – Port-1
Mgmt PVC
Name
HVirtual circuit is a management
link that terminates in the unit,
where
Name
is the link name
DLCI
DLCI
(16–1007)
or
(
VPI,VCI
) (0–15,31–255)
Identifies an individual link.