Parker Hannifin
146 Aries User Guide
TCI Transfer Commanded Current
Type Transfer Product Rev
Syntax <a_>TCI Aries 1.0
Units Amps
Range N/A
Default N/A
Response TCI: <*>5.ØØ
See Also DMTIC, DMTICD, DMTIP, TDICNT, TDIMAX
The TCI command reports the commanded motor current in amps (peak of
sine).
TDHRS Transfer Operating Hours
Type Transfer Product Rev
Syntax <a_>TDHRS Aries 1.0
Units Lifetime operating hours
(resolution is hours)
Range Hour counter rolls over at 536854528 hours
Default N/A
Response TDHRS: <*>16
See Also RESET, TERRLG
The TDHRS command reports the lifetime number of hours that the Aries
drive has had power applied (AC mains or Control power).
TDICNT Transfer Continuous Current Ratin g
Type Transfer Product Rev
Syntax <a_>TDICNT Aries 1.0
Units Amps rms
Range Drive Dependant
Default N/A
Response TDICNT: <*>1Ø
See Also DMTIC, DMTICD, DMTIP, TCI, TDIMAX
The TDICNT command reports the continuous current rating of the drive in
amps rms.