Parker Hannifin
26 Aries User Guide
Figure 3 Cabinet losses for AR-13xx when connected to a Parker MPM1421CSJ motor
Shaft Power
Voltage 0W* 700W 1300W
120 VAC 14W 82W 130W
240 VAC 25W 95W 146W
* Drive enabled, zero torque.
Table 8 AR-13xx Power Dissipation