Parker Hannifin
Chapter 7 Troubleshooting 161
Error Resolution
EØ—Motor Configuration
Warning
The motor rating is too high for the drive, and the
drive is using its own limits for safety reasons.
E1—Motor Configuration Error One of the motor parameters is set to zero (0).
Look at the additional errors to find which
parameters are set at zero (0). Refer to your
motor specifications for the correct value.
E3—Max Inductance = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero (0) value. Refer to
your motor specifications for the correct value.
(DMTIND)
E4—Rated Speed = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
E5—DPOLE = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DPOLE)
E6—Resistance = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DMTRES)
E7—Ke = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DMKE)
E8—Continuous Current = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DMTIC)
E9—Peak Current = Ø This parameter is set to zero (0). To correct the
error, you must set a non-zero value. Refer to
your motor specifications for the correct value.
(DMTIP)
E1Ø—Continuous Current Too
High
The continuous current of the motor is higher than
the continuous current rating of the drive. Use the
continuous current rating for the drive.
E11—Torque Rating Too High
for Drive
The motor’s torque rating is too high for the power
level of the drive. Use the drive’s torque rating.
E12—Peak Current Too High The peak current of the motor is higher than the
peak current rating of the drive. Use the drive’s
value for peak current.
E13 - Inertia = Ø This parameter is set to zero (0). The drive will not
enable Velocity or Position Modes. To correct the
error, you must set to a non-zero value. Refer to
your motor specifications for the correct value.
(DMTJ)
E14 – Damping = Ø This parameter is set to zero (0). The drive will not
enable Velocity or Position Modes. To correct the
error, you must set to a non-zero value. Refer to
your motor specifications for the correct value.
(DMTD)