Parker Hannifin
Chapter 6 Command Reference 147
TDIMAX Transfer Maximum Current Rating
Type Transfer Product Rev
Syntax <a_>TDIMAX Aries 1.0
Units Amps rms
Range N/A
Default N/A
Response TDIMAX: <*>1Ø
See Also DMTIC, DMTICD, DMTIP, TCI, TDICNT
The TDIMAX command reports the maximum current rating of the drive in
amps rms.
TDMIN Transfer Operating Minutes
Type Transfer Product Rev
Syntax <a_>TDMIN Aries 1.0
Units Minutes
Range Ø to 59
Default N/A
Response TDMIN: <*>35
See Also TDHRS, TDSEC, TERRLG
The TDMIN command reports the minutes portion of the lifetime operating
hours that the Aries drive has had power applied (AC Mains or Control
power).
TDSEC Transfer Operating Milliseconds
Type Transfer Product Rev
Syntax <a_>TDSEC Aries 1.0
Units Milliseconds
Range Ø to 59999
Default N/A
Response TDSEC: <*>35678
See Also TDHRS, TDMIN
The TDSEC command reports the milliseconds portion of the lifetime
operating hours that the Aries drive has had power applied (AC Mains or
Control power).