Parker Hannifin
Chapter 3 Electrical Installation 39
Power Supply

Input Power

The mains motor power supply and control power supply for the Aries Drive
must meet the following requirements.
Model Requirements
Motor Input Power
AR-01xx, AR-02xx, AR-04xx,
AR-08xx, AR-13xx
(L1, L2)
120/240 VAC, 50/60 Hz, single phase
AR-20xE
(L1, L2, L3)
240 VAC, 50/60 Hz, single phase or
three phase
AR-30xE
(L1, L2, L3)
240 VAC, 50/60 Hz, three phase only
Control Input Power
All models
(C1, C2)
120/240 VAC, single phase
Figure 15 Input Power Requirements

Mains/Input Power Connector

AR-01xx, AR-02xx,AR-04xx, AR-08xx, AR-13xx
Connector Type.......................................Removable screw terminal
Terminals........................................7
Pitch................... 0.200 in (5.08 mm)
Wire Range....................12-26 AWG
.......................................14-27 SWG
................................(0.12-3.30 mm2)
Wire Strip length.. 0.31 in (7.87 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)
AR-20xE, AR-30xE
Connector Type.......................................Non-Removable screw terminal
Terminals......................................10
Pitch........................ 0.315 in (8 mm)
Wire Range....................10-22 AWG
.......................................12-23 SWG
....................................(0.5-4.0 mm2)
Wire Strip length.... 0.25 in (6.5 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)