Inputs—Enable, Reset
The drive Enable and Reset inputs are optically isolated inputs. Current is
limited internally for input voltage control of 5 to 24 volt logic. The Anode (+)
and Cathode () are on separate connector pins to allow significant flexibility
in wiring to different styles of interface.
Description Min Max Units
Turn-on time 1 ms
Turn-off time 1 ms
Guaranteed on voltage 4 VDC
Guaranteed off voltage 2 VDC
Maximum forward voltage 30 VDC
Maximum reverse voltage -30 VDC
Forward current 3 12 mA
Note: All parameters are at the connector pin.
Table 30 Inputs—Enable and Reset Electrical/Timing Characteristics
Outputs—Encoder
Description Min Typical Max Units
Output Frequency
(pre-quadrature) 5 MHz
Input Voltage High * 2.4 V
Input Voltage Low * 0.5 V
* Based on 120 differential load impedance.
Note: All parameters are at the connector pin.
Note: Aries encoder is a hardware pass-through; therefore, you cannot change output
resolution.
Table 31 Outputs—Encoder Outputs Electrical/Timing Characteristics
Outputs—Fault
Description Min Typical Max Units
Blocking Voltage 30 V
Continuous Load Current 10 mA
Output Saturation Voltage
(at 1.0 mA) 1.0 V
* Based on 120 differential load impedance.
Note: All parameters are at the connector pin.
Table 32 Outputs— Fault outputs Electrical/Timing Characteristics