266Character string length in the control characters packet must be 5 (MPCL control characters) or 7 (ENQ/IMD command character).

267Baud rate selection must be 0 (1200), 1 (2400), 2 (4800), 3 (9600), 4 (19200), 5 (38400), 6 (57600), or 7 (115200). Resend the communication settings packet.

268Word length selection must be 0 (7 bits), or 1 (8 bits). Resend the communication settings packet.

269Stop bits selection must be 0 (1 bit), or 1 (2 bits). Resend the communication settings packet.

270Parity selection must be 0 (none), 1 (odd), or 2 (even). Resend the communication settings packet.

271Flow control selection must be 0 (none), 1 (DTR), 2 (CTS/RTS), or 3 (XON/XOFF). Resend the communication settings packet.

272Internal code page selection must be 0 (Internal), 1 (ANSI), 2 (DOS 437), 3 (DOS 850), 4 (1250- Latin 2), 5 (1251- Cyrillic), 6 (1252- Latin 1), 7 (1253- Greek), 8 (1254- Turkish), 9 (1255- Hebrew), 10 (1256- Arabic), 11 (1257- Baltic), 12 (1258- Vietnamese), 13 (852- Latin 2), 14 (855- Russian), 15 (857- IBM Turkish), 16 (860- DOS Portuguese), 17 (Wingdings), 18 (Macintosh), 19 (UNICODE), 20 (BIG5), 21 (GB), 22 (SJIS to SJIS), 23 (GB to GB), 24 (BIG5 to BIG5), or 25 (KSC to KSC).

273Cut adjustment must be -300to 300 dots.

282RS232 Trailer string is too long. Use a maximum of 3 characters.

283ENQ Trailer string is too long. Use a maximum of 3 characters.

284The buffer type must be T (Transmit), R (Receive), I (Image), F (Format), or D (Downloadable Fonts).

Diagnostics and Errors 8-13

Page 179
Image 179
Paxar 9402, 9403 manual