C O D A B A R I N F O

The CODABARINFO data structure contains scanner configuration information about Codabar bar codes. To read these values, applications call scnGetCodabarInfo; to set these values, they call scnSetCodabarInfo.

typedef struct _CodabarInfo

{

unsigned char uchEnable; unsigned char uchLength1; unsigned char uchLength2; unsigned char uchEnableCLSIEdit; unsigned char uchEnableNOTISEdit;

} CODABARINFO;

Field

Description

 

uchEnable

Enable/disable the ability to scan Codabar

 

bar codes.

 

 

 

Default: SCN_DISABLE

 

uchLength1

Specifies lengths (including start and stop

uchLength2

characters) for Codabar bar codes. You

 

can specify one or two lengths, a range of

 

lengths, or that any length is valid. Enter

 

values as follows:

 

 

Option

uchLength1

uchLength2

 

1 Length

Value

0

 

2 Lengths

Higher Value Lower Value

 

Range

Min. Value

Max. Value

 

Any length

0

0

 

Default: 5 (uchLength1) and 55

 

(uchLength2)

 

5-2 Programmer’s Manual

Page 156
Image 156
Paxar Gold 6037EX manual D a B a R I N F O