Field | Description | |
|
| |
uchChkDgtAlgorithm | Specifies whether the scanner should | |
| check the integrity of I 2 of 5 bar codes to | |
| ensure they comply with either the Uniform | |
| Symbology Specification (USS) or Optical | |
| Product Code Council (OPCC) algorithms. | |
| Values are: | |
| 0 | Do not check the integrity |
| 1 | Check the integrity against the |
|
| USS algorithm |
| 2 | Check the integrity against the |
|
| OPCC algorithm |
| Default: 0 | |
uchXmitCheckDigit | Enable/disable the requirement to transmit | |
| check digits with the data. | |
| Default: SCN_DISABLE | |
uchCvtI2of5toEAN13 | Enable/disable the requirement to convert | |
| ||
| bar codes, and transmit them as EAN13 | |
| bar codes. | |
| To use this parameter, enable uchEnable, | |
| set the length to 14, and ensure the data | |
| has a leading zero and a valid EAN 13 | |
| check digit. | |
| Default: SCN_DISABLE |
Data Structure Reference