The GENERALINFO data structure contains general scanner configuration information. To read these values, applications call scnGetGeneralInfo; to set these values, they call scnSetGeneralInfo.

typedef struct _GeneralInfo

{

unsigned char uchLaserOnTime; unsigned char uchPowerMode; unsigned char uchTriggerMode; unsigned char uchSameSymbolTMO; unsigned char uchLinearCodeSecur; unsigned char uchBiDirRedun;

} GENERALINFO;

Field

Description

uchLaserOnTime

The maximum time (in increments of .1

 

seconds) of a scan. Values are 5-99.

 

Default: 30

uchPowerMode

Specifies whether power remains on or

 

the scanner goes into low power mode

 

after a scan. If uchTriggerMode is 1

 

(Continuous) and uchPowerMode is 1

 

(Low Power), the scanner remains

 

continually on. Values are:

 

0

Continually On

 

1

Low Power

 

Default: 1

uchTriggerMode

The method that starts the scanner. If

 

uchTriggerMode is 1 (Continuous) and

 

uchPowerMode is 1 (Low Power), the

 

scanner remains continually on. Values

 

are:

 

 

0

Trigger

 

1

Continuous (always on)

 

Default: 0