![](/images/new-backgrounds/1186820/186820325x1.webp)
G E N E R A L I N F O
The GENERALINFO data structure contains general scanner configuration information. To read these values, applications call scnGetGeneralInfo; to set these values, they call scnSetGeneralInfo.
typedef struct _GeneralInfo
{
unsigned char uchLaserOnTime; unsigned char uchPowerMode; unsigned char uchTriggerMode; unsigned char uchSameSymbolTMO; unsigned char uchLinearCodeSecur; unsigned char uchBiDirRedun;
} GENERALINFO;
Field | Description | |
uchLaserOnTime | The maximum time (in increments of .1 | |
| seconds) of a scan. Values are | |
| Default: 30 | |
uchPowerMode | Specifies whether power remains on or | |
| the scanner goes into low power mode | |
| after a scan. If uchTriggerMode is 1 | |
| (Continuous) and uchPowerMode is 1 | |
| (Low Power), the scanner remains | |
| continually on. Values are: | |
| 0 | Continually On |
| 1 | Low Power |
| Default: 1 | |
uchTriggerMode | The method that starts the scanner. If | |
| uchTriggerMode is 1 (Continuous) and | |
| uchPowerMode is 1 (Low Power), the | |
| scanner remains continually on. Values | |
| are: |
|
| 0 | Trigger |
| 1 | Continuous (always on) |
| Default: 0 |
Data Structure Reference