Field

Description

 

 

uchEnableSuppRedun

The number of times to scan bar codes

 

without supplementals before

 

transmission. Five or more is

 

recommended when scanning a mix of

 

UPC/EAN bar codes with and without

 

supplementals. You must set

 

uchEnableSupps is set to 2 when setting

 

this parameter. Single digit numbers

 

must have a leading zero. Values are 2-

 

20.

 

 

Default: 7

uchXmitUPCAChkDgt

Enable/disable the requirement to

 

transmit UPCA bar codes with the check

 

digit.

 

 

Default: SCN_ENABLE

uchXmitUPCEChkDgt

Enable/disable the requirement to

 

transmit UPCE0 bar codes with the

 

check digit.

 

Default: SCN_ENABLE

uchXmitUPCE1ChkDgt

Enable/disable the requirement to

 

transmit UPCE1 bar codes with the

 

check digit.

 

Default: SCN_ENABLE

uchUPCAPreamble

Specifies how to transmit lead-in

 

characters for UPCA bar codes. Values

 

are:

 

 

0

Do not transmit

 

1

Transmit system character

 

2

Transmit system character and

 

 

country code

 

Default: 1