| Field | Description |
|
|
|
|
| ||
| uchEnableC32Prefix | Enable/disable the ability to add “A” as a | ||
|
| prefix to all Code 32 bar codes. You must | ||
|
| enable uchCvtC39toC32 when enabling | ||
|
| this parameter. |
| |
|
| Default: SCN_DISABLE |
| |
| uchLength1 | Specifies lengths (including check digits) | ||
| uchLength2 | for Code 39 bar codes. You can specify | ||
|
| one or two lengths, a range of lengths, or | ||
|
| that any length is valid. If | ||
|
| uchEnableFullASCII is enabled, a range or | ||
|
| any length is preferred. Enter values as | ||
|
| follows: |
|
|
|
| Option | uchLength1 uchLength2 | |
|
| 1 Length | Value | 0 |
|
| 2 Lengths | High Value | Low Value |
|
| Range | Min. Value | Max. Value |
|
| Any length | 0 | 0 |
|
| Default: 2 (uchLength1) and 55 | ||
|
| (uchLength2) |
| |
| uchVerifyCheckDigit | Enable/disable the ability to check the | ||
|
| integrity of Code 39 bar codes. When this | ||
|
| parameter is enabled, only Code 39 | ||
|
| symbols with a modulo 43 check digit are | ||
|
| decoded. |
|
|
|
| Default: SCN_DISABLE |
| |
| uchXmitCheckDigit | Enable/disable the ability to transmit check | ||
|
| digits with the data. |
| |
|
| Default: SCN_DISABLE |
| |
| uchEnableFullASCII | Enable/disable the ability to scan Full | ||
|
| ASCII Code 39 bar codes. The scanner | ||
|
| cannot distinguish Code 39 bar codes from | ||
|
| Full ASCII Code 39 bar codes. Do not | ||
|
| enable uchEnableTrioptic and | ||
|
| uchEnableFullASCII at the same time. | ||
|
| Default: SCN_DISABLE |
| |
|
|
|