Installation

Guidelines

Trunk Assignments for Single-Cabinet Systems

Programming is not required to associate trunk ports with slot locations. However, you must use programming to specify that a combination of ISDN and analog trunks is installed, and you must also specify how many ISDN channels are used.

Fractional ISDN per port assignments require the VB-43511A version of the loop start trunk card. The older VB-43511 version may be used with fractional ISDN but requires that the trunks be assigned in blocks of 8.

Table 2-2. ISDN and analog trunk assignments, DBS 40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk

 

Fractional ISDN

 

Fractional ISDN

 

 

 

 

Number

 

using 16 Channels

 

using 8 Channels

 

 

 

 

1

 

 

ISDN channel 16

 

 

Analog trunk 1

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

ISDN channel 9

 

 

Analog trunk 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

ISDN channel 8

 

 

ISDN channel 8

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

ISDN channel 1

 

 

ISDN channel 1

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Since the

DBS 40 supports a maximum of 16 trunks, all 23

 

 

 

 

channels of the ISDN cannot be used.

 

 

 

Table 2-3. ISDN and analog trunk assignments, DBS 72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk

23-Channel ISDN

 

Fractional ISDN

 

Fractional ISDN

 

Number

 

 

 

 

using 16 Channels

 

using 8 Channels

 

1

 

Analog trunk 1

 

Analog trunk 1

 

Analog trunk 1

 

2

 

ISDN channel 23

Analog trunk 2

 

Analog trunk 2

 

 

 

 

 

8

 

ISDN channel 17

Analog trunk 8

 

Analog trunk 8

 

 

 

 

 

 

 

 

9

 

ISDN channel 16

ISDN channel 16

 

Analog trunk 9

 

 

 

 

 

16

 

ISDN channel 9

 

ISDN channel 9

 

Analog trunk 16

 

 

 

 

 

 

 

 

 

17

 

ISDN channel 8

 

ISDN channel 8

 

ISDN channel 8

 

 

 

 

 

24

 

ISDN channel 1

 

ISDN channel 1

 

ISDN channel 1

 

 

 

 

 

 

 

 

 

 

 

Revised April 2000

DBS-EX23-530

2-5

Page 23
Image 23
Philips DBS-EX23-530 manual Trunk Assignments for Single-Cabinet Systems