Philips DBS-EX23-530 manual Trunk Settings Programming Reference, =Do not reset

Models: DBS-EX23-530

1 118
Download 118 pages 27.38 Kb
Page 80
Image 80

Trunk Settings

Programming Reference

Trunk Settings

Parameter

Trunk Type

 

 

Description

Determines whether the trunk circuit is an analog loop start, analog

 

ground start, analog DID, T1, CID, or ISDN.

 

Note: For changes to this parameter to take effect, the system

 

must be powered down, then back up again.

 

 

Programming

FF2 (1-64)# 21# (0-5)#

 

 

Options

0= Loop start

 

1=Ground start

 

2=DID

 

3=T1

 

4=CID

 

5=ISDN

 

 

Parameter

ISDN Data Reset

 

 

Description

Resets the ISDN settings stored in SRAM (Static Random Access

 

Memory). The reset restores these settings to default values.

 

 

Programming

FF1 9# 1# (0-1)#

 

Note: If you enter a “1,” the following display appears:

 

CONFIRM

 

0: NO 1: YES

 

The purpose of this display is to make sure you want to reset the

 

data. Enter a 0 or 1, depending on whether you want to complete

 

or cancel the reset.

 

0=Do not reset

 

1=Reset

 

 

Options

0=No (retain settings)

 

1=Yes (clear settings)

 

 

4-28

DBS-EX23-530

Revised April 2000

Page 80