Philips DBS-EX23-530 manual Alarm Relay Controls, =Off Alarm relay does not close

Models: DBS-EX23-530

1 118
Download 118 pages 27.38 Kb
Page 77
Image 77

Programming Reference

Alarm Settings

Alarm Relay Controls

Parameter

Yellow Alarm Relay

 

 

Description

Determines whether the system closes the alarm relay on the ISDN

 

MDF card in the event of yellow alarms.

 

The alarm relay can be connected to an external alarm device such

 

as a buzzer. The external alarm device must be purchased sepa-

 

rately; it is not provided with the DBS ISDN.

 

(The “Yel Alm Det” parameter on page 4-21determines how many

 

yellow alarms occur before the relay closes.)

 

 

Programming

Master cabinet: FF1 9# 4# 4# 4# 1# (0-1)#

 

Slave cabinet: FF1 9# 4# 5# 4# 1# (0-1)#

 

 

Options

0=Off (Alarm relay does not close.)

 

1=On (Alarm relay closes.)

 

 

 

 

Parameter

Red Alarm Relay

 

 

Description

Determines whether the system closes the alarm relay on the ISDN

 

MDF card in the event of red alarms.

 

The alarm relay can be connected to an external alarm device such

 

as a buzzer. The external alarm device must be purchased sepa-

 

rately; it is not provided with the DBS ISDN.

 

A red alarm indicates a loss of frame (OOF) or loss of signal has

 

continued for over 2.5 seconds.

 

(The “Red Alm Det” parameter on page 4-21determines how

 

many red alarms occur before the relay closes.)

 

 

Programming

Master cabinet: FF1 9# 4# 4# 4# 2# (0-1)#

 

Slave cabinet: FF1 9# 4# 5# 4# 2# (0-1)#

 

 

Options

0=Off (Alarm relay does not close.)

 

1=On (Alarm relay closes.)

 

 

Revised April 2000

DBS-EX23-530

4-25

Page 77
Image 77
Philips DBS-EX23-530 manual Alarm Relay Controls, =Off Alarm relay does not close