Guidelines

Installation

Table 2-4. ISDN and analog trunk assignments, DBS 96

Trunk

23-Channel ISDN

Fractional ISDN

Fractional ISDN

Number

 

using 16 Channels

using 8 Channels

1

Analog trunk 1

Analog trunk 1

Analog trunk 1

8

Analog trunk 8

Analog trunk 8

Analog trunk 8

 

 

 

 

9

Analog trunk 9

Analog trunk 9

Analog trunk 9

10

ISDN channel 23

 

 

16

ISDN channel 17

Analog trunk 16

Analog trunk 16

 

 

 

 

17

ISDN channel 16

ISDN channel 16

Analog trunk 17

24

ISDN channel 9

ISDN channel 9

Analog trunk 24

 

 

 

 

25

ISDN channel 8

ISDN channel 8

ISDN channel 8

32

ISDN channel 1

ISDN channel 1

ISDN channel 1

 

 

 

 

Trunk Assignments for Double-Cabinet Systems

When ISDN is used in a two-cabinet system, the number of ISDN channels that can be assigned in each cabinet depends on the master/slave designation.

Fractional ISDN per port assignments require the VB-43511A version of the loop start trunk card. The older VB-43511 version may be used with fractional ISDN but requires that the trunks be assigned in blocks of 8.

The following table shows the maximum number of ISDN channels that can be assigned in two-cabinet systems.

2-6

DBS-EX23-530

Revised April 2000

Page 24
Image 24
Philips DBS-EX23-530 manual Trunk Assignments for Double-Cabinet Systems