Image 90

Special ISDN Function Codes

Programming Reference

Parameter

Forced Re-synchronization

 

 

Description

Re-synchronizes the DBS ISDN with the public network.

 

Notes:

 

1. Forced re-synchronization disconnects existing calls.

 

2. Before executing this code, you must first enter the program-

 

ming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 6

 

Slave: ON/OFF #95 6

 

 

Options

None. Re-synchronization begins as soon as the code is entered.

 

 

 

 

Parameter

Historical Error Clearance

 

 

Description

Clears the error counters for the following alarms:

 

yellow

 

red

 

framing loss

 

slip rate

 

loss of signal

 

sync loss

 

Note: Before executing this code, you must first enter the pro-

 

gramming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 7

 

Slave: ON/OFF #95 7

 

 

Options

None. The counters are cleared as soon as the code is entered.

 

 

 

 

Parameter

Alarm Relay Clear

 

 

Description

Clears (opens) the alarm relay on the ISDN MDF card.

 

Note: Before executing this code, you must first enter the pro-

 

gramming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 8

 

Slave: ON/OFF #95 8

 

 

Options

None. The relay is cleared as soon as the code is entered.

 

 

 