Installation

 

Guidelines

Table 2-5. Maximum ISDN assignments for two-cabinet systems

 

 

 

 

 

 

 

 

 

 

System Size

Master

Slave

 

 

 

DBS 40 + DBS 40

8 analog trunks

16 ISDN trunks

 

 

 

 

 

 

 

 

 

DBS 72 + DBS 72

16 analog trunks

23 ISDN trunks

 

 

 

 

 

1 analog trunk

 

 

 

DBS 96 + DBS 40

23 ISDN trunks

16 ISDN trunks

 

 

 

 

9 analog trunks

 

 

 

 

DBS 96 + DBS 72

23 ISDN trunks

23 ISDN trunks

 

 

 

 

9 analog trunks

1 analog trunk

 

 

 

DBS 96 + DBS 96

23 ISDN trunks

23 ISDN trunks

 

 

 

 

9 analog trunks

9 analog trunks

 

Two-cabinet systems use the same trunk numbering scheme as single- cabinet systems: analog trunks are numbered from “1” upward; ISDN trunk channels are numbered downward from the highest channel used.

Tables 2-6through 2-10show trunk numbering for two-cabinet systems using the maximum number of ISDN channels.

Table 2-6. ISDN and analog trunk assignments, DBS 40 + 40 (16-channel fractional ISDN in the slave)

Trunk

Master Cabinet

Slave Cabinet

Number

 

 

1

Analog trunk 1

 

Ν/Α

8

Analog trunk 8

 

 

 

 

9

 

ISDN channel 16

N/A

16

 

ISDN channel 9

 

 

 

17

 

ISDN channel 8

Ν/Α

24

 

ISDN channel 1

 

 

 

Revised April 2000

DBS-EX23-530

2-7

Page 25
Image 25
Philips DBS-EX23-530 manual System Size Master Slave, Trunk Master Cabinet Slave Cabinet Number