Philips DBS-EX23-530 manual Disable, None

Models: DBS-EX23-530

1 118
Download 118 pages 27.38 Kb
Page 82
Image 82

Trunk Settings

Programming Reference

Parameter

Auto Progress Setting

 

 

Description

Specifies whether progress messages are supplied by the DBS to

 

the ISDN span (master or slave cabinet).

 

 

Programming

FF1 9# 4# 4# 5# 2# (0-1)# (master cabinet)

 

FF1 9# 4# 5# 5# 2# (0-1)# (slave cabinet)

 

 

 

Options

0

- Disable

 

1

- Enable

 

 

 

Parameter

Network Facility Setting

 

 

Description

Determines if a call is a Software Defined Network (SDN) call

 

(AT&T option) or general Megacom call.

 

 

Programming

FF1 9# 4# 4# 5# 3# (0-1)# (master cabinet)

 

FF1 9# 4# 5# 5# 3# (0-1)# (slave cabinet)

 

 

 

Options

0

- None

 

1

- SDN

 

2

- Megacom

 

 

 

Parameter

ISDN CO Type

 

 

Description

Specifies the type of CO connected to the ISDN span.

 

 

Programming

FF1 9# 4# 4# 5# 4# (0-3)# (master cabinet)

 

FF1 9# 4# 5# 5# 4# (0-3)# (slave cabinet)

 

 

 

Options

0

- 4ESS

 

1

- 5ESS

 

2

- Reserved

 

3

- DMS100

 

 

 

4-30

DBS-EX23-530

Revised April 2000

Page 82
Image 82