Trunk Settings

Programming Reference

Parameter

Auto Progress Setting

 

 

Description

Specifies whether progress messages are supplied by the DBS to

 

the ISDN span (master or slave cabinet).

 

 

Programming

FF1 9# 4# 4# 5# 2# (0-1)# (master cabinet)

 

FF1 9# 4# 5# 5# 2# (0-1)# (slave cabinet)

 

 

 

Options

0

- Disable

 

1

- Enable

 

 

 

Parameter

Network Facility Setting

 

 

Description

Determines if a call is a Software Defined Network (SDN) call

 

(AT&T option) or general Megacom call.

 

 

Programming

FF1 9# 4# 4# 5# 3# (0-1)# (master cabinet)

 

FF1 9# 4# 5# 5# 3# (0-1)# (slave cabinet)

 

 

 

Options

0

- None

 

1

- SDN

 

2

- Megacom

 

 

 

Parameter

ISDN CO Type

 

 

Description

Specifies the type of CO connected to the ISDN span.

 

 

Programming

FF1 9# 4# 4# 5# 4# (0-3)# (master cabinet)

 

FF1 9# 4# 5# 5# 4# (0-3)# (slave cabinet)

 

 

 

Options

0

- 4ESS

 

1

- 5ESS

 

2

- Reserved

 

3

- DMS100

 

 

 

4-30

DBS-EX23-530

Revised April 2000

Page 82
Image 82