Alarm Settings

Programming Reference

Alarm Transmission Options

Parameter

Yellow Alarm Send

 

 

Description

Determines whether the DBS sends a yellow alarm signal to the

 

CO.

 

 

Programming

Master cabinet: FF1 9# 4# 4# 1# 7# (0-1)#

 

Slave cabinet: FF1 9# 4# 5# 1# 7# (0-1)#

 

 

Options

0=No

 

1=Yes

 

 

Parameter

Red Alarm Detection

 

 

Description

The default value for this parameter is determined by network

 

specifications. It should not be changed.

 

If a red alarm occurs, the “CFA” LED on the ISDN card lights.

 

Also, if the “Red Alm Relay” parameter (page 4-25)is turned on,

 

the alarm relay on the ISDN MDF card closes.

 

Note: For changes to this parameter to take effect, the system

 

must be powered down, then back up again.

 

 

Programming

Master cabinet: FF1 9# 4# 4# 2#1# (0-5)#

 

Slave cabinet: FF1 9# 4# 5# 2# 1# (0-5)#

 

 

Options

0-5

 

 

Values

0=4

 

1=6

 

2=8

 

3=10

 

4=12

 

5=14

 

 