Alarm Settings

Programming Reference

Parameter

Loss of Signal Counter

 

 

Description

Determines how many instances of loss of signal occur before a

 

Signal Loss FF key is lit.

 

The FF key lights when the counter exceeds the specified number

 

within a 24-hour period.

 

(See page 4-35for instructions on programming ISDN FF keys.)

 

 

Programming

Master cabinet: FF1 9# 4# 4# 3# 4# (0-9000)#

 

Slave cabinet: FF1 9# 4# 5# 3# 4# (0-9000)#

 

 

Options

0-9000/24 hours (9000)

Parameter

Sync Loss Counter

 

 

Description

Determines how many instances of sync loss occur before a Sync

 

Loss FF key is lit.

 

The FF key lights when the counter exceeds the specified number

 

within a 24-hour period.

 

(See page 4-35for instructions on programming FF alarm keys.)

 

 

Programming

Master cabinet: FF1 9# 4# 4# 3# 5# (0-9000)#

 

Slave cabinet: FF1 9# 4# 5# 3# 5# (0-9000)#

 

 

Options

0-9000/24 hours (9000)

Parameter

Yellow Alarm Counter

 

 

Description

Determines how many yellow alarm indications occur before a

 

Yellow Alarm FF key is lit.

 

The FF key lights activated when the counter exceeds the specified

 

number within a 24-hour period.

 

(See page 4-35for instructions on programming FF alarm keys.)

 

 

Programming

Master cabinet: FF1 9# 4# 4# 3# 6# (0-9000)#

 

Slave cabinet: FF1 9# 4# 5# 3# 6# (0-9000)#

 

 

Options

0-9000/24 hours (9000)

 

 