Programming Reference

Alarm Settings

Parameter

Relay Reset

 

 

Description

Determines whether the ISDN alarm relay is cleared (opened) auto-

 

matically or manually.

 

If cleared automatically, the relay is opened approximately one sec-

 

ond after the alarm condition ceases.

 

If cleared manually, the relay can be opened by entering the Alarm

 

Relay Clear code.

 

To enter the Alarm Relay Clear code, first enter the programming

 

authorization code (#98 9999), then enter one of the following

 

codes:

 

(Master cabinet: ON/OFF #94 8)

 

(Slave cabinet: ON/OFF #95 8)

 

 

Programming

Master cabinet: FF1 9# 4# 4# 4# 6# (0-1)#

 

Slave cabinet: FF1 9# 4# 5# 4# 6# (0-1)#

 

 

Options

0=Auto

 

1=Manual

 

 

Revised April 2000

DBS-EX23-530

4-27

Page 79
Image 79