System-Wide Timers

Programming Reference

Parameter

Ringing Timer (T301)

 

 

Description

Determines how long the called party will ring before the DBS will

 

disconnect the call.

 

 

Programming

FF1 9# 4# 2# 2# (0-15)#

 

 

Options

0-10

 

0=180 sec.

 

1=20 sec.

 

2=40 sec.

 

3=60 sec.

 

.

 

.

 

.

 

11=220 sec.

 

12=240 sec.

 

13=240 sec.

 

14=240 sec.

 

15=Infinite

 

 

 

 

Parameter

Call Setup Timer (T303)

 

 

Description

Determines the time limit for a CO to respond to an outgoing call

 

attempt.

 

 

Programming

FF1 9# 4# 2# 3# (0-10)#

 

 

Options

0-10

 

0=4 sec.

 

1=1 sec.

 

2=2 sec.

 

3=3 sec.

 

4=4 sec.

 

5=5 sec.

 

6=6 sec.

 

7=7 sec.

 

8=8 sec.

 

9=9 sec.

 

10=10 sec.

 

 

4-8

DBS-EX23-530

Revised April 2000

Page 60
Image 60
Philips DBS-EX23-530 manual System-Wide Timers Programming Reference, 15=Infinite, =4 sec