ISDN System SettingsProgramming Reference

Clock Settings

Parameter

Sync Source 1

 

 

Description

The Sync Card (installed on the CPC-EX) provides a method of syn-

 

chronizing the DBS with the public network. This parameter deter-

 

mines the first clocking source for network synchronization. If the

 

first source fails, the system will switch to the second source. The

 

system will attempt to go back to the first source based on the value

 

entered under “Network Re-sync Timer” (page 4-7).

 

The system considers a clock source to have failed when the slip

 

rate error counter is exceeded within a 24-hour period. (See page 4-

 

23 for instructions on setting the slip rate error counter.)

 

In most cases, the 1st sync source is set to “1.” See page 3-5for a list

 

of typical sync source settings for single and double-cabinet sys-

 

tems.

 

Notes:

 

1. The “free run” setting is the only setting that can be entered for

 

more than one sync source.

 

2. For changes to this parameter to take effect, the system must be

 

powered down, then back up again.

 

 

Programming

FF1 9# 4# 1# 2# (1-3)#

 

 

Options

1=ISDN of the master cabinet (synchronizes clocking with the pub-

 

lic network)

 

2=ISDN of the slave cabinet (synchronizes clocking with the public

 

network)

 

3=Free run (internal clocking)

 

 