Special ISDN Function Codes

Programming Reference

Special ISDN Function Codes

The following function codes are used for troubleshooting and maintenance of the ISDN Interface.

These codes can be entered remotely by dialing into the DBS and entering the ISDN maintenance mode. To enter the ISDN maintenance mode, type an uppercase “T” at the REMT prompt.

Parameter

Loopback 1

 

 

Description

Loopbacks provide diagnostic tests of the ISDN circuit or the

 

ISDN connection to the CO.

 

This loopback initiates a loopback with the CO. The loopback

 

takes place through the Line Build Out (LBO) chip on the ISDN

 

card.

 

This loopback is typically used to check the continuity between

 

the CO, CSU, MDF, and ISDN card.

 

Note: Before executing this loopback, you must first enter the pro-

 

gramming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 0 (0 or 1)

 

Slave: ON/OFF #95 0 (0 or 1)

 

 

Options

0=Off

 

1=On

 

 

 

 

Parameter

Loopback 2

 

 

Description

Loopbacks provide diagnostic tests of the ISDN circuit or the

 

ISDN connection to the CO.

 

This loopback also initiates a loopback with the CO. Loopback 2

 

is identical to Loopback 1, except that it loops back through the

 

Framer chip on the ISDN card, thereby testing more of the ISDN

 

circuitry.

 

Note: Before executing this loopback, you must first enter the pro-

 

gramming authorization code (#98 9999).

 

 

Execution

Master: ON/OFF #94 1 (0 or 1)

 

Slave: ON/OFF #95 1 (0 or 1)

 

 

Options

0=Off

 

1=On

 

 

4-36

DBS-EX23-530

Revised April 2000

Page 88
Image 88
Philips DBS-EX23-530 manual Special Isdn Function Codes Programming Reference