Sensaphone® Model 1104 User’s Manual

3.4Summary of the Alarm Dial-Out Process

Action—Response

Programmable Feature

 

 

 

1. THE MODEL 1104 DETECTS AN

Recognition Time

ALERT CONDITION

 

This is the programmed

 

 

An alert condition is not the same as

 

waiting period to determine if

a valid alarm—the condition must

 

an alert condition has

continue for the programmed time

 

persisted long enough to be

period, or Recognition Time, before

 

considered a valid alarm. If

it is recognized as a valid alarm.

 

the sensor returns to normal

2. A VALID ALARM IS CONFIRMED

 

within recognition time, then

 

no alarm will occur.

 

 

An audible, on-site alarm message

Call Delay

begins and continues until the alarm

 

 

is acknowledged. (If the Mute

 

This is the programmed

feature is turned on, there is no on-

 

waiting period, before the

site message.) Call Delay is

 

first telephone number is

activated.

 

called, to report an alarm.

3. DIAL-OUT BEGINS

Intercall Time

Dial-out begins by calling telephone

 

This is the programmed

number 1 to report an alarm.

 

waiting period, in between

If there is no acknowledgment, the

 

sequential dialing of

Model 1104 waits the programmed

 

telephone numbers, to report

Intercall Time before dialing

 

an alarm.

subsequent telephone numbers. Dial-

Max Calls

out continues in this manner, cycling

 

 

through the remaining telephone

 

This is the total number of

numbers, for the programmed Max

 

telephone calls that will be

Calls.

 

dialed in response to any

4. THE ALARM IS

 

valid alarm. Telephone

 

numbers are dialed

ACKNOWLEDGED

 

 

sequentially, and continue to

 

 

When the alarm is acknowledged, the

 

cycle until the maximum

dial-out process is cancelled and the

 

number of calls is reached. If

audible, on-site alarm message stops.

 

no acknowledgment occurs,

 

 

then at the completion of

 

 

Max Calls, all alarms are

 

 

automatically acknowledged.

 

 

 

32

Page 32
Image 32
Phonetics 1104 user manual Action-Response Programmable Feature, Alert Condition