Polycom MGC-50/MGC-100 First Entry IP Configuration, IP Configuration Change on Xpek and pSOS OS

Models: MGC-50/MGC-100

1 172
Download 172 pages 45.37 Kb
Page 57
Image 57

MGC Hardware and Installation Manual

First Entry IP Configuration

This following section describes the first entry IP Configuration for pSOSystem and XPEK Operating Systems.

IP Configuration Change on XPEK and pSOS OS

1.Connect a Hub or cross-over LAN cable between the laptop’s LAN connection and the LAN connection of the Control Unit.

2.On the laptop, click Control Panel ->NetworkConnection->Local Area Connection.

3.In the Local Area Connection - General dialog box, click the Properties button.

4.In the Local Area Connection Properties dialog box and click Use the following IP address.

5.Type the IP address 129.254.4.7 (of the laptop as part of the network segment on the MCU).

6.Click OK.

7.Run the MGC Manager application.

8.Define a new MCU:

a.In the Browser pane, right-click the MCUs Network icon, and then click New MCU.

2-35