Powerware Energy Management System EMS
Upgrade Kit 208/120V, 380/220V, 400/230V, 415/240V User’s Guide
Requesting a Declaration of Conformity
Special Symbols
Three−phase alternating current PROTECTIVE CONDUCTOR TERMINAL
Page
Table of Contents
Installation
Initial System Configuration
Setup Options
Serial Port Service
Maintenance
Specifications
Troubleshooting
Chapter
Introduction
The following options for the EMS−UGK are available
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
Safety Warnings
D A N G E R
C A U T I O N
CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS
Consignes de sécurité
A T T E N T I O N
D A N G E R
WICHTIGE SICHERHEITSANWEISUNGEN AUFBEWAREN
Sicherheitswarnungen
W A R N U N G
A C H T U N G
INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ESTAS INSTRUCCIONES
Advertencias de Seguridad
P E L I G R O
P R E C A U C I Ó N
Installation
Inspecting the Equipment
Unpacking the Cabinet
Chapter
Checking the Parts List
Verify that the following items are included with the EMS−UGK
Tools Required
S Pliers or other appropriate tool for installing wire taps
To assemble the components, the following tools may be needed
S Phillips #2 screwdriver
Installing the Hardware
Verify that at least two wall anchors attach to studs within the wall
Figure 4 shows the location of the two serial ports
Electrical Connections
W A R N I N G
C A U T I O N
C A U T I O N
S If installing conduit not supplied, plan for adequate conduit
Figure 5. Wiring Overview Example Installation
Table 4. Harness Sizing
A, B, C
Panel Connections and
Main Input Harness CTM
Figure 6. Harness Connections at the Electronics Module
Table 5. EMS−UGK Harness Connections
INSTALLATION
Figure 7. Panel Detail EMS−UGK−LV Model with Dual Panel Option Shown
If installing dual panels, repeat Step 5 for the second panel
Coil and secure any excess cable away from other conductors
Install each CT around the appropriate subfeed breaker wire
C A U T I O N
12. Choose an option for connecting the phases for voltage sensing
C A U T I O N
Proceed to Step 15 on page
Verify the wire taps are completely closed around the wires
24. Continue to the following section
Initial Configuration
Installing the Software Configuration Tool
Initial System Configuration
Figure 15. System Status Page Connected
Window
Calc to have the software automatically calculate the VA rating
7. Configure the following required settings
voltage. For example, for two 225A panels and a 120V nominal
9. Click Save Sys Config to save the settings to the EMS−UGK. Depending on communication speed, updates take effect within 15-20 seconds
sounds for each new alarm and can be turned off by
12. Configure the following Miscellaneous Features
13. Configure the following Building Alarm Settings
Configuration Using the Software Configuration Tool
main panel breaker alarms and zeroes the panel percent
4. Configure the following settings for the selected panel
6. Repeat Steps 3 through 5 to configure the remaining panels
10. Configure the following settings for the selected breaker
Initial Panel and Breaker Configuration Using the Display
12. Continue to the following section, Installation
INSTALLATION
Advanced Metering Installation
Reset Function
Operation
Breaker Numbering
Chapter
Control Panel Functions
The following table shows the indicator status and description
000.0 000.0 000.0
Display Functions
EATON EMS−UGK
PROFILE SETUP SET UP
Menu Map
The following tables show the basic menu structure
Table 7. Panel Meters
Table 8. Breaker Meters
Setup Options
Use the arrow keys to enter the password for the level you
want to access, then select DONE to display the options for
Use the arrow keys to enter the new password A-Z
Configuring Panels Containing Branch Circuit Breakers
Control Panel Configuration
Accessing Configuration
Configuring Panels Containing Subfeed Breakers
Panel breaker rating in amps
Subfeed breaker rating in amps
Configuring Branch Circuit Breakers
NOTE Configure a breaker only if its CT is installed
7. When all branch circuit configuration is complete, select the
Viewing Panel Meters
Viewing Breaker Meters
Chapter 4 Communication
Communication Options
Installing Communication Features
Serial Port Service
X−Slot Card
Control Terminals
W A R N I N G
Relay Output Contacts Alarm Relay
Programmable Signal Inputs Building Alarms
COMMUNICATION
Maintenance
Replacing the Power Xpert Gateway Series 1000 Card
Recycling the Used Equipment
Updating the Firmware
Rewiring and Reconfiguring the Installation
D A N G E R
W A R N I N G
C A U T I O N
Specifications
Table 12. Dimensions and Weight
Chapter
Table 13. Communication Options
Table 16. Display Optional
Table 15. Environmental and Safety
Table 14. Electrical Input
Table 17. Metering
Main current 6A
SPECIFICATIONS
Chapter 7 Troubleshooting
Typical Alarms and Conditions
Service and Support
All other countries Call your local service representative
TROUBLESHOOTING
Warranty
Limited Factory Warranty
Powerware Energy Management System EMS Upgrade Kit
Chapter
WARRANTY
Page
1642017241