P R I N T E R C O N F I G U R A T I O N
Parallel/LAN Interface Items
Since the optional LAN interface goes into the Parallel port, these interface parameters are the same.
INTERFACE MENU
Parallel/LAN
Emulation
Emulation Epson
Possible Values: Epson*, IBM Proprinter, DEC LA120,
TTY, Printek, ANSI X3.64,
Genicom 3840, Genicom 3410
This item selects the emulation to be used whenever the parallel port is active. The emulation should be set to match the type of printer your software supports.
LAN Setup
Possible Values: On, Off*
LAN Setup Off
This item enables or disables the ability to control the optional Ethernet interface card from the front panel. When set to On, the Serial Interface is not available, and menu items for the Ethernet card follow. Consult your Network Administrator before changing any of these items.
Note: Setting this item to On when the optional Ethernet interface card is not present or optional control
IP Address Method
IP Address Auto
57