Programming662
SkipOver Perforation
ASCII Hex Decimal
PSeries N/A N/A N/A
Serial ESC N n 1B 4E n 27 78 n
Purpose Selects
the number of lines (at the
current line spacing) for the paper skip at the
bottom of the perforated page.
where n = 1 to 127 to select the number of lines to skip. If the value of n exceeds the
current forms length, it is ignored.
Comment The
actual distance set is the product of
n
and the
current line spacing. The factory
default
value is to disable skipover perforation. Y
ou can specify the default value.
Setting a new forms length (ESC C) resets skipover perforation to zero.
This feature is disabled whenever vertical tabs are set.
You
can also select skipover perforation from
the control panel; however
, vertical
tabs
within the skipover perforation zone, as
set by the control panel, are ignored.
The
control code
skipover perforation setting from the host computer overrides the
control
panel setting.