CHAPTER 10

INSTALLATION

Introduction

This chapter explains the P3000 Series installation procedures. Read this chapter carefully before in- stalling and operating the printer. Perform the procedures in the order presented. The following topics are discussed in this chapter:

Power Requirements

Page 10–1

Site Requirements

Page 10–2

Shipping Restraints

Page 10–4

Cable Connections

Page 10–6

Preliminary Test

Page 10–8

Power Requirements

A label on the back of the printer near the power cord indicates the voltage and frequency require- ments. The printer must be connected to the specified power source in the proper range, 92 to 132 VAC or 184 to 264 VAC, at 50 to 60 Hz. The printer automatically senses and adjusts itself to conform to the proper voltage range. Primary circuit protection is contained in the printer. Consult an electrician if printer operation affects local electrical lines.

IMPORTANT

Printronix recommends that printer power be supplied from a separate circuit pro- tected at 20 amps for 120 VAC, or 10 amps for 240 VAC at 50 or 60 Hz.

WICHTIG

Es wird empfohlen, dass der Strom von einem separaten Wechselstromkreis dem Drucker zugefü hrt wird, der mit 20 A fü r 120 V oder 10 A fü r 240 V geschü tzt ist und 50 oder 60 Hz hat.

Installation

10–1

Page 197
Image 197
Printronix P3000 Series manual Chapter Installation, Power Requirements