Remote Maintenance by Telnet (mshell)
67
5
The following example shows how set the protocol for an address.
msh> snmp

number

{ip | ipx}

address

Note
When using the TCP/IP protocol, input ip followed by a space and then
the IP address.
When using the IPX/SPX protocol, input ipx followed by a space and then
the IPX address followed by a decimal and then the MAC address of the
Network Interface Board.
The following is an example of how to configure registration number 3 with
the IP address 192.168.15.16.
msh> snmp 3 ip 192.168.15.16
The following is an example of how to configure registration number 3 with
the IPX address 7390A448, and the MAC address 00:00:74:62:5C:65.
msh> snmp 3 ipx 7390A448.000074625C65

Changing the Password

Use the passwd command to change the remote maintenance password.
Important
Be sure not to forget or lose the password.
Note
The default factory password is “password”.
AInput “passwd”.
msh> passwd
BInput the current password.
Old password:
CInput the new password.
New password:
Note
The password must consist of 3 to 8 alphanumeric characters and symbols.
Upper and lower case characters are considered unique. For example, R is
different from r.
The password is the same as that used in the configuration of the Network
Interface Board using a Web browser and that used in the NIB Setup Tool.
If you change a password on the mshell, the other passwords are also
changed.
DInput the new password once again.
Retype new password: