4.3.3Connection of the Container Stacker 2 and Finisher / Finisher SR5000

[FS-104H] (No RoHS Compliance Unit)

1)Remove the two M3 screws and the discharging brush from the Container Stacker 2.

2)Install the Guide plate (G) with the Static electricity eliminator (“FRONT” letter is surface.) by using the two M3 Screws. (Be careful that the hair of the Static electricity eliminator does not fall.)

3)Install the guide plate (H), connecting stay and main MT plate.

Container stacker 2

Connecting stay

 

 

 

Guide plate (G)

 

 

 

 

 

 

M4 screws

M3 screws

M3 screws with washer

Static electricity eliminator

M4 screws

Guide plate (H)

Main MT plate

4) Remove the rear covers from the Engine, Container Stacker 2 and Finisher.

II

L

002

Preparation for Installation 4-37

Page 85
Image 85
Ricoh 70E installation manual M4 screws M3 screws