1.4 Tools Required

 

 

Table 1.2 Tools Required

 

 

Item

Name

Usage

 

1

Cutter

Unpacking

 

2

Phillips Screw Driver NO.2 shaft

Removing and installing the screw for covers

 

 

length; approx. 40 and 100mm

 

 

3

Adjustable Open End Wrench

Leveling the bolt

 

 

 

Fixing the leveling the bolts

 

4

Level Meter

Installation the Container Stacker

1.5 Environmental Conditions

 

Table 1.3 Environmental Conditions

 

Items

 

Value

 

Temperature

10

~32 °C (50 ~ 89.6°F)

 

Humidity

20

~80 %RH

 

 

(Wet Bulb 26 °C (78.8 °F ) max.)

 

Altitude

0 to 2,100 m (0 to 7,000 feet) max.

1.6 Input Line Voltage

Table 1.4 Print Engine Input Line Voltage

Input Line Voltage

AC 200V ~ AC 240V

Phase

Single Phase, two wires and grounding wire

Frequency

50/60 Hz ±1Hz

Transient (Static)

±10%

Transient (Dynamic)

–18% / +15% 500ms

Drop out

-100%, 20ms

II

L

010

Installation Requirements 1-2